Untitled Document
 

Untitled Document
Untitled Document
Full Text                                                                            Full-Text Online       
Quantitative multiplex detection of plant pathogens using a novel ligation probe-based system coupled with universal, high-throughput real-time PCR on OpenArrays
Doorn. R. V      Szemes. M      Bonants. P      Kowalchuk. G. A      Salles. J. F      Ortenberg. E      Schoen. C. D      
BMC Genomics 2007, Vol. 8, p276, 14p ;  2007  [Vol.8]  Pages:276-290
Abstract
Background: Diagnostics and disease-management strategies require technologies to enable the simultaneous detection and quantification of a wide range of pathogenic microorganisms. Most multiplex,quantitative detection methods available suffer from compromises between the level of multiplexing, throughput and accuracy of quantification. Here, we demonstrate the efficacy of a novel, high-throughput,ligation-based assay for simultaneous quantitative detection of multiple plant pathogens. The ligation probes, designated Plant Research International-lock probes (PRI-lock probes), are long oligonucleotides with target complementary regions at their 5 and 3 ends. Upon perfect target hybridization, the PRI-lock probes are circularized via enzymatic ligation, subsequently serving as template for individual, standardized amplification via unique probe-specific primers. Adaptation to OpenArrays™, which can accommodate up to 3072 33 nl PCR amplifications, allowed high-throughput real-time quantification. The assay combines the multiplex capabilities and specificity of ligation reactions with high-throughput real-time PCR in the OpenArray™, resulting in a flexible, quantitative multiplex diagnostic system. Results: The performance of the PRI-lock detection system was demonstrated using 13 probes targeting several significant plant pathogens at different taxonomic levels. All probes specifically detected their corresponding targets and provided perfect discrimination against non-target organisms with very similar ligation target sites. The nucleic acid targets could be reliably quantified over 5 orders of magnitude with a dynamic detection range of more than 104. Pathogen quantification was equally robust in single target versus mixed target assays. Conclusion: This novel assay enables very specific, high-throughput, quantitative detection of multiple pathogens over a wide range of target concentrations and should be easily adaptable for versatile diagnostic purposes.
Keywords